Improve shims_logger function to get full details.
authorRomain Forlot <romain.forlot@iot.bzh>
Tue, 14 Mar 2017 23:48:49 +0000 (00:48 +0100)
committerRomain Forlot <romain.forlot@iot.bzh>
Thu, 16 Mar 2017 16:21:57 +0000 (17:21 +0100)
Change-Id: I752db65cb3fbca4d33b932f3a0c597adfaf79903
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
src/diagnostic/diagnostic-manager.cpp

index 6cf220c..21a599d 100644 (file)
@@ -380,11 +380,16 @@ bool diagnostic_manager_t::shims_send(const uint32_t arbitration_id, const uint8
        return can_bus_dev->shims_send(arbitration_id, data, size);
 }
 
-void diagnostic_manager_t::shims_logger(const char* m, ...)
+void diagnostic_manager_t::shims_logger(const char* format, ...)
 {
-       DEBUG(binder_interface, "%s", m);
+       va_list args;
+       va_start(args, format);
+
+       char buffer[256];
+       vsnprintf(buffer, 256, format, args);
+
+       DEBUG(binder_interface, "shims_logger: %s", buffer);
 }
 
 void diagnostic_manager_t::shims_timer()
 {}
-