Fix: wrong socket variable called.
authorRomain Forlot <romain.forlot@iot.bzh>
Thu, 9 Mar 2017 01:26:05 +0000 (02:26 +0100)
committerRomain Forlot <romain.forlot@iot.bzh>
Thu, 16 Mar 2017 16:10:40 +0000 (17:10 +0100)
Change-Id: Ib09b084e7202d184abf73cf92fea4afbcf4acf47
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
src/can/can-bus-dev.cpp

index a6429ed..389154b 100644 (file)
@@ -175,7 +175,7 @@ int can_bus_dev_t::send_can_message(can_message_t& can_msg)
 
        f = can_msg.convert_to_canfd_frame();
 
-       if(can_socket_)
+       if(can_socket_.socket())
        {
                nbytes = ::sendto(can_socket_.socket(), &f, sizeof(struct canfd_frame), 0,
                        (struct sockaddr*)&txAddress_, sizeof(txAddress_));