Keeping raw socket until diagnostic_manager is fully migrated
authorRomain Forlot <romain.forlot@iot.bzh>
Wed, 3 May 2017 15:54:20 +0000 (17:54 +0200)
committerRomain Forlot <romain.forlot@iot.bzh>
Wed, 3 May 2017 15:54:20 +0000 (17:54 +0200)
Change-Id: I8cb170613c003bbdb39240eb809b8cefcad6cb35
Signed-off-by: Romain Forlot <romain.forlot@iot.bzh>
CAN-binder/low-can-binding/can/can-bus-dev.cpp
CAN-binder/low-can-binding/can/can-bus-dev.hpp

index 07f921f..99cad71 100644 (file)
@@ -67,8 +67,16 @@ void can_bus_dev_t::configure()
        if (can_socket_)
        {
                const int timestamp_on = 1;
+               const int canfd_on = 1;
 
                DEBUG(binder_interface, "%s: CAN Handler socket correctly initialized : %d", __FUNCTION__, can_socket_.socket());
+
+               // try to switch the socket into CAN_FD mode
+               if (can_socket_.setopt(SOL_CAN_RAW, CAN_RAW_FD_FRAMES, &canfd_on, sizeof(canfd_on)) < 0)
+               {
+                       NOTICE(binder_interface, "%s: Can not switch into CAN Extended frame format: %s", __FUNCTION__, ::strerror(errno));
+               }
+
                if (can_socket_.setopt(SOL_SOCKET, SO_TIMESTAMP, &timestamp_on, sizeof(timestamp_on)) < 0)
                        WARNING(binder_interface, "%s: setsockopt SO_TIMESTAMP error: %s", __FUNCTION__, ::strerror(errno));
        }
index 8b4cf47..e9c2d20 100644 (file)
@@ -22,7 +22,7 @@
 #include <string>
 #include <thread>
 
-#include "../utils/socketcan.hpp"
+#include "../utils/socketcan-raw.hpp"
 
 class can_bus_t;
 class can_message_t;
@@ -34,7 +34,7 @@ class can_bus_dev_t
 {
 private:
        std::string device_name_; ///< a string identifier identitfying the linux CAN device.
-       utils::socketcan_t can_socket_;
+       utils::socketcan_raw_t can_socket_;
 
        int index_;