X-Git-Url: https://gerrit.automotivelinux.org/gerrit/gitweb?a=blobdiff_plain;f=openxc.proto;h=c2b7f7c2159a4af5bb9fa6b8169112dd45226029;hb=68ce7c57c76496efb28c385428b0e2d797d8df74;hp=6b79c36fc740f0df98f744b67fd350ec5fa8de81;hpb=f8ea5374f584310fbd7521b41385a71eb7c613d3;p=apps%2Fagl-service-can-low-level.git diff --git a/openxc.proto b/openxc.proto index 6b79c36f..c2b7f7c2 100644 --- a/openxc.proto +++ b/openxc.proto @@ -4,17 +4,114 @@ option java_package = "com.openxc"; option java_outer_classname = "BinaryMessages"; message VehicleMessage { - enum Type { RAW = 1; TRANSLATED = 2; } + enum Type { RAW = 1; TRANSLATED = 2; DIAGNOSTIC = 3; CONTROL_COMMAND = 4; + COMMAND_RESPONSE = 5; } optional Type type = 1; optional RawMessage raw_message = 2; optional TranslatedMessage translated_message = 3; + optional DiagnosticResponse diagnostic_response = 4; + optional ControlCommand control_command = 5; + optional CommandResponse command_response = 6; } message RawMessage { optional int32 bus = 1; optional uint32 message_id = 2; - optional uint64 data = 3; + optional bytes data = 3; +} + +message ControlCommand { + enum Type { + VERSION = 1; + DEVICE_ID = 2; + DIAGNOSTIC = 3; + PASSTHROUGH = 4; + ACCEPTANCE_FILTER_BYPASS = 5; + PAYLOAD_FORMAT = 6; + PREDEFINED_OBD2_REQUESTS = 7; + } + + optional Type type = 1; + optional DiagnosticControlCommand diagnostic_request = 2; + optional PassthroughModeControlCommand passthrough_mode_request = 3; + optional AcceptanceFilterBypassCommand acceptance_filter_bypass_command = 4; + optional PayloadFormatCommand payload_format_command = 5; + optional PredefinedObd2RequestsCommand predefined_obd2_requests_command = 6; +} + +message DiagnosticControlCommand { + enum Action { ADD = 1; CANCEL = 2; } + + optional DiagnosticRequest request = 1; + optional Action action = 2; +} + +message PassthroughModeControlCommand { + optional int32 bus = 1; + optional bool enabled = 2; +} + +message AcceptanceFilterBypassCommand { + optional int32 bus = 1; + optional bool bypass = 2; +} + +message PayloadFormatCommand { + enum PayloadFormat { + JSON = 1; + PROTOBUF = 2; + } + + optional PayloadFormat format = 1; +} + +message PredefinedObd2RequestsCommand { + optional bool enabled = 1; +} + +message CommandResponse { + optional ControlCommand.Type type = 1; + optional string message = 2; + optional bool status = 3; +} + +message DiagnosticRequest { + enum DecodedType { NONE = 1; OBD2 = 2; } + + optional int32 bus = 1; + optional uint32 message_id = 2; + optional uint32 mode = 3; + optional uint32 pid = 4; + // TODO we are capping this at 8 bytes for now - need to change when we + // support multi-frame responses + optional bytes payload = 5; + optional bool multiple_responses = 6; + optional double frequency = 7; + optional string name = 8; + optional DecodedType decoded_type = 9; +} + +message DiagnosticResponse { + optional int32 bus = 1; + optional uint32 message_id = 2; + optional uint32 mode = 3; + optional uint32 pid = 4; + optional bool success = 5; + optional uint32 negative_response_code = 6; + // TODO we are capping this at 8 bytes for now - need to change when we + // support multi-frame responses + optional bytes payload = 7; + optional double value = 8; +} + +message DynamicField { + enum Type { STRING = 1; NUM = 2; BOOL = 3; } + + optional Type type = 1; + optional string string_value = 2; + optional double numeric_value = 3; + optional bool boolean_value = 4; } message TranslatedMessage { @@ -23,14 +120,8 @@ message TranslatedMessage { optional Type type = 1; optional string name = 2; - - optional string string_value = 3; - optional double numeric_value = 4; - optional bool boolean_value = 5; - - optional string string_event = 6; - optional double numeric_event = 7; - optional bool boolean_event = 8; + optional DynamicField value = 3; + optional DynamicField event = 4; } // TODO we should also consider having an enum type, having each specific