3 option java_package = "com.openxc";
4 option java_outer_classname = "BinaryMessages";
6 message VehicleMessage {
7 enum Type { RAW = 1; TRANSLATED = 2; DIAGNOSTIC = 3; CONTROL_COMMAND = 4;
8 COMMAND_RESPONSE = 5; }
10 optional Type type = 1;
11 optional RawMessage raw_message = 2;
12 optional TranslatedMessage translated_message = 3;
13 optional DiagnosticResponse diagnostic_response = 4;
14 optional ControlCommand control_command = 5;
15 optional CommandResponse command_response = 6;
19 optional int32 bus = 1;
20 optional uint32 message_id = 2;
21 optional bytes data = 3;
24 message ControlCommand {
25 enum Type { VERSION = 1; DEVICE_ID = 2; DIAGNOSTIC = 3; }
27 optional Type type = 1;
28 optional DiagnosticRequest diagnostic_request = 2;
31 message CommandResponse {
32 optional ControlCommand.Type type = 1;
33 optional string message = 2;
36 message DiagnosticRequest {
37 optional int32 bus = 1;
38 optional uint32 message_id = 2;
39 optional uint32 mode = 3;
40 optional uint32 pid = 4;
41 // TODO we are capping this at 8 bytes for now - need to change when we
42 // support multi-frame responses
43 optional bytes payload = 5;
44 optional bool multiple_responses = 6;
45 optional double factor = 7;
46 optional double offset = 8;
47 optional double frequency = 9;
48 optional string name = 10;
51 message DiagnosticResponse {
52 optional int32 bus = 1;
53 optional uint32 message_id = 2;
54 optional uint32 mode = 3;
55 optional uint32 pid = 4;
56 optional bool success = 5;
57 optional uint32 negative_response_code = 6;
58 // TODO we are capping this at 8 bytes for now - need to change when we
59 // support multi-frame responses
60 optional bytes payload = 7;
61 optional double value = 8;
64 message DynamicField {
65 enum Type { STRING = 1; NUM = 2; BOOL = 3; }
67 optional Type type = 1;
68 optional string string_value = 2;
69 optional double numeric_value = 3;
70 optional bool boolean_value = 4;
73 message TranslatedMessage {
74 enum Type { STRING = 1; NUM = 2; BOOL = 3;
75 EVENTED_STRING = 4; EVENTED_NUM = 5; EVENTED_BOOL = 6;}
77 optional Type type = 1;
78 optional string name = 2;
79 optional DynamicField value = 3;
80 optional DynamicField event = 4;
83 // TODO we should also consider having an enum type, having each specific
84 // message defined as a protobuf