1 /* Automatically generated nanopb constant definitions */
2 /* Generated by nanopb-0.3.1 at Sat Sep 27 19:18:56 2014. */
6 #if PB_PROTO_HEADER_VERSION != 30
7 #error Regenerate this file with the current version of nanopb generator.
12 const pb_field_t openxc_VehicleMessage_fields[7] = {
13 PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_VehicleMessage, type, type, 0),
14 PB_FIELD( 2, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, raw_message, type, &openxc_RawMessage_fields),
15 PB_FIELD( 3, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, translated_message, raw_message, &openxc_TranslatedMessage_fields),
16 PB_FIELD( 4, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, diagnostic_response, translated_message, &openxc_DiagnosticResponse_fields),
17 PB_FIELD( 5, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, control_command, diagnostic_response, &openxc_ControlCommand_fields),
18 PB_FIELD( 6, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_VehicleMessage, command_response, control_command, &openxc_CommandResponse_fields),
22 const pb_field_t openxc_RawMessage_fields[4] = {
23 PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_RawMessage, bus, bus, 0),
24 PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_RawMessage, message_id, bus, 0),
25 PB_FIELD( 3, BYTES , OPTIONAL, STATIC , OTHER, openxc_RawMessage, data, message_id, 0),
29 const pb_field_t openxc_ControlCommand_fields[5] = {
30 PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_ControlCommand, type, type, 0),
31 PB_FIELD( 2, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_ControlCommand, diagnostic_request, type, &openxc_DiagnosticControlCommand_fields),
32 PB_FIELD( 3, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_ControlCommand, passthrough_mode_request, diagnostic_request, &openxc_PassthroughModeControlCommand_fields),
33 PB_FIELD( 4, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_ControlCommand, acceptance_filter_bypass_command, passthrough_mode_request, &openxc_AcceptanceFilterBypassCommand_fields),
37 const pb_field_t openxc_DiagnosticControlCommand_fields[3] = {
38 PB_FIELD( 1, MESSAGE , OPTIONAL, STATIC , FIRST, openxc_DiagnosticControlCommand, request, request, &openxc_DiagnosticRequest_fields),
39 PB_FIELD( 2, ENUM , OPTIONAL, STATIC , OTHER, openxc_DiagnosticControlCommand, action, request, 0),
43 const pb_field_t openxc_PassthroughModeControlCommand_fields[3] = {
44 PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_PassthroughModeControlCommand, bus, bus, 0),
45 PB_FIELD( 2, BOOL , OPTIONAL, STATIC , OTHER, openxc_PassthroughModeControlCommand, enabled, bus, 0),
49 const pb_field_t openxc_AcceptanceFilterBypassCommand_fields[3] = {
50 PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_AcceptanceFilterBypassCommand, bus, bus, 0),
51 PB_FIELD( 2, BOOL , OPTIONAL, STATIC , OTHER, openxc_AcceptanceFilterBypassCommand, bypass, bus, 0),
55 const pb_field_t openxc_CommandResponse_fields[4] = {
56 PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_CommandResponse, type, type, 0),
57 PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_CommandResponse, message, type, 0),
58 PB_FIELD( 3, BOOL , OPTIONAL, STATIC , OTHER, openxc_CommandResponse, status, message, 0),
62 const pb_field_t openxc_DiagnosticRequest_fields[10] = {
63 PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_DiagnosticRequest, bus, bus, 0),
64 PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, message_id, bus, 0),
65 PB_FIELD( 3, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, mode, message_id, 0),
66 PB_FIELD( 4, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, pid, mode, 0),
67 PB_FIELD( 5, BYTES , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, payload, pid, 0),
68 PB_FIELD( 6, BOOL , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, multiple_responses, payload, 0),
69 PB_FIELD( 7, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, frequency, multiple_responses, 0),
70 PB_FIELD( 8, STRING , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, name, frequency, 0),
71 PB_FIELD( 9, ENUM , OPTIONAL, STATIC , OTHER, openxc_DiagnosticRequest, decoded_type, name, 0),
75 const pb_field_t openxc_DiagnosticResponse_fields[9] = {
76 PB_FIELD( 1, INT32 , OPTIONAL, STATIC , FIRST, openxc_DiagnosticResponse, bus, bus, 0),
77 PB_FIELD( 2, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, message_id, bus, 0),
78 PB_FIELD( 3, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, mode, message_id, 0),
79 PB_FIELD( 4, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, pid, mode, 0),
80 PB_FIELD( 5, BOOL , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, success, pid, 0),
81 PB_FIELD( 6, UINT32 , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, negative_response_code, success, 0),
82 PB_FIELD( 7, BYTES , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, payload, negative_response_code, 0),
83 PB_FIELD( 8, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DiagnosticResponse, value, payload, 0),
87 const pb_field_t openxc_DynamicField_fields[5] = {
88 PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_DynamicField, type, type, 0),
89 PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_DynamicField, string_value, type, 0),
90 PB_FIELD( 3, DOUBLE , OPTIONAL, STATIC , OTHER, openxc_DynamicField, numeric_value, string_value, 0),
91 PB_FIELD( 4, BOOL , OPTIONAL, STATIC , OTHER, openxc_DynamicField, boolean_value, numeric_value, 0),
95 const pb_field_t openxc_TranslatedMessage_fields[5] = {
96 PB_FIELD( 1, ENUM , OPTIONAL, STATIC , FIRST, openxc_TranslatedMessage, type, type, 0),
97 PB_FIELD( 2, STRING , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, name, type, 0),
98 PB_FIELD( 3, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, value, name, &openxc_DynamicField_fields),
99 PB_FIELD( 4, MESSAGE , OPTIONAL, STATIC , OTHER, openxc_TranslatedMessage, event, value, &openxc_DynamicField_fields),
104 /* Check that field information fits in pb_field_t */
105 #if !defined(PB_FIELD_32BIT)
106 /* If you get an error here, it means that you need to define PB_FIELD_32BIT
107 * compile-time option. You can do that in pb.h or on compiler command line.
109 * The reason you need to do this is that some of your messages contain tag
110 * numbers or field sizes that are larger than what can fit in 8 or 16 bit
113 PB_STATIC_ASSERT((pb_membersize(openxc_VehicleMessage, raw_message) < 65536 && pb_membersize(openxc_VehicleMessage, translated_message) < 65536 && pb_membersize(openxc_VehicleMessage, diagnostic_response) < 65536 && pb_membersize(openxc_VehicleMessage, control_command) < 65536 && pb_membersize(openxc_VehicleMessage, command_response) < 65536 && pb_membersize(openxc_ControlCommand, diagnostic_request) < 65536 && pb_membersize(openxc_ControlCommand, passthrough_mode_request) < 65536 && pb_membersize(openxc_ControlCommand, acceptance_filter_bypass_command) < 65536 && pb_membersize(openxc_DiagnosticControlCommand, request) < 65536 && pb_membersize(openxc_TranslatedMessage, value) < 65536 && pb_membersize(openxc_TranslatedMessage, event) < 65536), YOU_MUST_DEFINE_PB_FIELD_32BIT_FOR_MESSAGES_openxc_VehicleMessage_openxc_RawMessage_openxc_ControlCommand_openxc_DiagnosticControlCommand_openxc_PassthroughModeControlCommand_openxc_AcceptanceFilterBypassCommand_openxc_CommandResponse_openxc_DiagnosticRequest_openxc_DiagnosticResponse_openxc_DynamicField_openxc_TranslatedMessage)
116 #if !defined(PB_FIELD_16BIT) && !defined(PB_FIELD_32BIT)
117 /* If you get an error here, it means that you need to define PB_FIELD_16BIT
118 * compile-time option. You can do that in pb.h or on compiler command line.
120 * The reason you need to do this is that some of your messages contain tag
121 * numbers or field sizes that are larger than what can fit in the default
124 PB_STATIC_ASSERT((pb_membersize(openxc_VehicleMessage, raw_message) < 256 && pb_membersize(openxc_VehicleMessage, translated_message) < 256 && pb_membersize(openxc_VehicleMessage, diagnostic_response) < 256 && pb_membersize(openxc_VehicleMessage, control_command) < 256 && pb_membersize(openxc_VehicleMessage, command_response) < 256 && pb_membersize(openxc_ControlCommand, diagnostic_request) < 256 && pb_membersize(openxc_ControlCommand, passthrough_mode_request) < 256 && pb_membersize(openxc_ControlCommand, acceptance_filter_bypass_command) < 256 && pb_membersize(openxc_DiagnosticControlCommand, request) < 256 && pb_membersize(openxc_TranslatedMessage, value) < 256 && pb_membersize(openxc_TranslatedMessage, event) < 256), YOU_MUST_DEFINE_PB_FIELD_16BIT_FOR_MESSAGES_openxc_VehicleMessage_openxc_RawMessage_openxc_ControlCommand_openxc_DiagnosticControlCommand_openxc_PassthroughModeControlCommand_openxc_AcceptanceFilterBypassCommand_openxc_CommandResponse_openxc_DiagnosticRequest_openxc_DiagnosticResponse_openxc_DynamicField_openxc_TranslatedMessage)
128 /* On some platforms (such as AVR), double is really float.
129 * These are not directly supported by nanopb, but see example_avr_double.
130 * To get rid of this error, remove any double fields from your .proto.
132 PB_STATIC_ASSERT(sizeof(double) == 8, DOUBLE_MUST_BE_8_BYTES)