openxc-utils : No send string but send array_object for signals
[apps/agl-service-can-low-level.git] / examples / hvac / signals.json
1 {   "name": "example",
2         "version": "2.0",
3         "extra_sources": [],
4         "initializers": [],
5         "loopers": [],
6         "buses": {},
7         "commands": [],
8         "messages": {
9                 "0x30": {
10                 "bus": "ls",
11                 "is_fd" : false,
12                 "is_extended": false,
13                 "is_j1939" : false,
14                 "signals": {
15                         "LeftTemperature": {
16                                 "generic_name": "hvac.temperature.left",
17                                 "bit_position": 0,
18                                 "bit_size": 8,
19                                 "factor": 1,
20                                 "offset": 0
21                         },
22                         "RightTemperature": {
23                                 "generic_name": "hvac.temperature.right",
24                                 "bit_position": 8,
25                                 "bit_size": 8,
26                                 "factor": 1,
27                                 "offset": 0
28                         },
29                         "Temperature": {
30                                 "generic_name": "hvac.temperature.average",
31                                 "bit_position": 16,
32                                 "bit_size": 8,
33                                 "factor": 1,
34                                 "offset": 0
35                         },
36                         "FanSpeed": {
37                                 "generic_name": "hvac.fan.speed",
38                                 "bit_position": 32,
39                                 "bit_size": 8,
40                                 "factor": 23.529411765,
41                                 "offset": 0
42                         }
43                 }
44         }
45 }
46 }